Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	
	
	
	
	 

Features of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
Relay Module KFD0-RO-Ex2
	2-channel isolated barrier
	24 V DC supply (loop powered)
	Logic input 15 V DC ... 30 V DC, non-polarized
	Relay contact output
	Up to SIL 3 acc. to IEC 61508
	Technical data of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	General specifications of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Signal type Digital Output
	Functional safety related parameters of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Safety Integrity Level (SIL) SIL 3
	Supply of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Rated voltage loop powered
	Power dissipation 0.8 W
	Input of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Connection side control side
	Connection terminals 7, 8, 9
	Input voltage 15 ... 30 V DC
	Input current ≤ 21 mA per channel
	Output of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Safety note Attention! Combination of output Ex i with output not Ex i is not permitted.
	If load voltage > 50 V, de-energize before removing the terminals.
	Connection side field side
	Connection terminals 1, 2, 3; 4, 5, 6
	Contact loading 230 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
	Energized/De-energized delay approx. 10 ms / approx. 5 ms
	Mechanical life 5 x 106 switching cycles
	Transfer characteristics of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Switching frequency < 10 Hz
	Galvanic isolation of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
	Output/Output basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
	Indicators/settings of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Display elements LEDs
	Labeling space for labeling at the front
	Directive conformity of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Electromagnetic compatibility 
	Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
	Low voltage 
	Directive 2014/35/EU EN 61010-1:2010
	Conformity of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Electromagnetic compatibility NE 21:2006
	Degree of protection IEC 60529:2001
	Ambient conditions of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Ambient temperature -20 ... 65 °C (-4 ... 149 °F)
	Mechanical specifications of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Degree of protection IP20
	Connection screw terminals
	Mass approx. 100 g
	Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
	Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
	Data for application in connection with hazardous areas of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	EU-Type Examination Certificate DMT 00 ATEX E 016
	Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC
	Ex-Hexagon II (1)D [Ex ia Da] IIIC
	Ex-Hexagon I (M1) [Ex ia Ma] I
	Output Ex ia
	Voltage 60 V
	Current 2 A
	Input 
	Maximum safe voltage 40 V DC (Attention! Um is no rated voltage.)
	Output 
	Contact loading 50 V AC/2 A ; 40 V DC/2 A (TÜV 00 ATEX 1621 X)
	Certificate TÜV 00 ATEX 1621 X
	Marking Ex-Hexagon II 3G Ex nA nC IIC T4
	Galvanic isolation 
	Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
	Output/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 60 V
	Directive conformity 
	Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
	International approvals of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	FM approval 
	Control drawing 116-0261
	CSA approval 
	Control drawing 116-0156
	IECEx approval IECEx BVS 10.0025
	Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
	General information of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
	Classifications of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	System Classcode
	ECLASS 11.0 27210101
	ECLASS 10.0.1 27210101
	ECLASS 9.0 27210101
	ECLASS 8.0 27210101
	ECLASS 5.1 27210121
	ETIM 8.0 EC001485
	ETIM 7.0 EC001485
	ETIM 6.0 EC001485
	ETIM 5.0 EC001485
	Similar models of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KFD0-RO-Ex2
	Relay Module
	2-channel isolated barrier, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
	KFD0-RSH-1.4S.PS2
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
	KFD0-RO-2
	Relay Module
	2-channel signal conditioner, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
	HiC5861
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 27.6 V DC, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
	HiC5861Y1
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 27.6 V DC, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	HiC5863
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 27.6 V DC, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
	HiC5863Y1
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 27.6 V DC, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
	KCD0-RSH-1.1D.1
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
	KCD0-RSH-1.1D.4
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
	KCD0-RSH-1.1E.1
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KFD0-RSH-1.1D.F1
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
	KFD0-RSH-1.1E.1
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
	KFD2-RSH-1.2D.FL2
	Relay Module
	1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
	KFD2-RSH-1.2D.FL3
	Relay Module
	1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
	KFD2-RSH-1.2E.L2
	Relay Module
	1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KFD2-RSH-1.2E.L3
	Relay Module
	1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508
	KFD0-RSH-1
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 16 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Up to SIL 3 acc. to IEC 61508
	KFD0-RSH-1-Y2
	Relay Module
	1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Test pulse immunity, Up to SIL 3 acc. to IEC 61508
	Ordering Codes of Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KFD2-STC3-EX1
	KFD2-ST2-E2
	Z 787.H
	KFD2-SR2-EX2.W
	KFD2-UT2-EX1
	KFD2-CD-EX1.32-0
	KFD2-CD-1.32
	KFD2-CD-Ex1.32-1
	KFD2-CR-EX1.30-200
	KFD2-STC4-EX1.H
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KFD2-CR4-1.2O
	KFD2-CR4-1.2O
	KFD2-GS-1.2W
	KFD0-CS-EX1.54
	KFD2-SCD2-EX1-LK
	KFD2-EB2.R4A.B 
	KFD2-STC4-EX1
	HD2-DM-B
	KFD2-SL2-EX.1B
	HD2-FBPS-1.25.360
	MBHD-FB-4R.YO
	Z961 
	KFD2-SR2-Ex1.W
	KFD2-SCD-EX1.LK
	KFD2-STC4-1
	KFD2-SH-EX1
	NCN3-F25F-N4-V1
	UPR-03
	KFD2-SCD2-Ex1.LK
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-1 KCD2-STC-EX1 KCD2-STC-EX1.2O KCD2-UT2-EX1 KFA6-SR2-Ex1.W KFD0-SD2-Ex1.1045 KFD2-CD2-EX1 KFD2-CRG2-EX1.D KFD2-DWB-1.D KFD2-EB2 KFD2-GU-1 KFD2-GUT-Ex1.D KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2 KFD2-SR2-Ex1.W.LB  KFD2-SR2-Ex2.W KFD2-ST2-Ex2 KFD2-STC4-1 KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-Ex2 KFD2-VR4-EX1.26
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KCD2-STC-Ex1 KCD2-STC-Ex1.ES KFD2-CRG2-Ex1.D KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.2W KFD2-STC4-Ex1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STC4-Ex2 KFU8-CRG2-Ex1.D KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.ES KCD2-STC-Ex1.ES.SP KCD2-STC-Ex1.SP KFD2-STC3-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y1 KFD2-STC5-Ex1 KFD2-STC5-Ex1.2O KFD2-STC5-Ex1.2O.H KFD2-STC5-Ex1.H KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV5-Ex1-1 KCD2-STC-Ex1.2O.DE KFD2-HLC-Ex1.D.4S KFD2-STV4-Ex1.2O-2 KCD2-STC-Ex1.HC KCD2-STC-Ex1.HC.SP KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV4-Ex1.2O-2 KFD2-STC3-Ex1 KCD2-STC-Ex1-Y1
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KCD2-STC-Ex1 KCD2-STC-Ex1.ES KFD2-CRG2-Ex1.D KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.2W KFD2-STC4-Ex1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STC4-Ex2 KFU8-CRG2-Ex1.D KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.ES KCD2-STC-Ex1.ES.SP KCD2-STC-Ex1.SP KFD2-STC3-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y1 KFD2-STC5-Ex1 KFD2-STC5-Ex1.2O KFD2-STC5-Ex1.2O.H KFD2-STC5-Ex1.H KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV5-Ex1-1 KCD2-STC-Ex1.2O.DE KFD2-HLC-Ex1.D.4S KFD2-STV4-Ex1.2O-2 KCD2-STC-Ex1.HC KCD2-STC-Ex1.HC.SP KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV4-Ex1.2O-2 KFD2-STC3-Ex1 KCD2-STC-Ex1-Y1
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-1 KCD2-STC-EX1 KCD2-STC-EX1.2O KCD2-UT2-EX1 KFA6-SR2-Ex1.W KFD0-SD2-Ex1.1045 KFD2-CD2-EX1 KFD2-CRG2-EX1.D KFD2-DWB-1.D KFD2-EB2 KFD2-GU-1 KFD2-GUT-Ex1.D KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2 KFD2-SR2-Ex1.W.LB KFD2-SR2-Ex2.W KFD2-ST2-Ex2 KFD2-STC4-1 KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-Ex2 KFD2-VR4-EX1.26 KFU8-FSSP-1.D NBB0,8-5GM25-E2 NBB1,5-8GM50-E0 NBB10-30GM40-Z0 NBB10-30GM50-E2 NBB15-30GM50-WO NBB15-30GM50-WS NBB15-U1-A2 NBB15-U1-A2-T NBB15-U1-E2 NBB15-U1-Z2 NBB2-12GM50-E0-V1 NBB2-12GM50-E2 NBB2-6,5M30-E0 NBB2-8GM30-E2-5M NBB20-L2-A2-V1-3G-3D NBB20-L2-E0-V1 NBB20-L2-E2-V1 NBB20-U1-A2 NBB20-U1-E0 NBB20-U1-E2 NBB3-V3-Z4 NBB4-12GM50-E0 NBB4-12GM50-E0-V1 NBB4-12GM50-E2-V1 NBB5-18GM50-E2-V1 NBB5-18GM60-A2-V1 NBB8-18GM50-E2-V1 NBB8-18GM60-A2-V1 NBN12-18GM50-E2-V1 NBN12-18GM50-E2-V1-Y261468 NBN15-30GM50-E0 NBN15-30GM50-E2-V1 NBN15-30GM60-A2 NBN25-30GM50-E2 NBN3-F31-E8-V1 NBN30-L2-E2-V1 NBN30-U1-A2 NBN30-U1-E2 NBN4-12GM50-E2 NBN4-12GM50-E2-V1 NBN40-L2-E2-V1 NBN40-U1-A2 NBN40-U1-A2-T NBN40-U1-Z2 NBN40-U1K-N0 NBN5-F7-E0 NBN5-F7-E2 NBN8-12GM50-E0-V1 NBN8-12GM50-E2-V1 NBN8-18GM50-E0 NBN8-18GM50-E2-V1 NBN8-18GM60-WS NCB10-30GM40-NO NCB15-30GM50-Z5 NCB50-FP-A2-P1 NCB8-18GM40-N0 NCN15-30GM40-Z1 NJ15+U1+DW1-10 NJ2-12GK-SN NJ2-V3-N NJ4-12GK-N NJ40-FP-SN-P1 NJ5-18GM-N NJ5-18GM50-A2-V1 NJ8-18GM-N NRB10-30GM50-E2-C-V1 NRB15-30GM50-E2-C-V1
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	 
	KCD2-SR-Ex1.LB KCD2-SR-Ex2 KFA6-DU-Ex1.D KFA6-ER-Ex1.W.LB KFA6-SOT2-Ex2 KFA6-SR2-Ex1.W KFA6-SR2-Ex1.W.LB KFA6-SR2-Ex2.W KFA6-SR2-Ex2.W.IR KFD2-DU-Ex1.D KFD2-ELD-Ex16 KFD2-ER-Ex1.W.LB KFD2-SH-Ex1 KFD2-SH-Ex1.T.OP KFD2-SOT3-Ex1.LB KFD2-SOT3-Ex1.LB.IO KFD2-SOT3-Ex2 KFD2-SOT3-Ex2.IO KFD2-SR2-Ex1.W KFD2-SR2-Ex1.W.LB KFD2-SR2-Ex2.W KFD2-SR3-Ex2.2S KFD2-SRA-Ex4 KFD2-ST3-Ex1.LB KFD2-ST3-Ex2 KHA6-SH-Ex1 KCD2-SON-Ex1 KCD2-SOT-Ex1.LB KCD2-SOT-Ex2 KCD2-SOT-Ex2.SP
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KCD2-SR-Ex1.LB.SP KCD2-SR-Ex2.SP KCD2-ST-Ex1.LB KCD2-ST-Ex2 KFA5-SOT2-Ex2 KFA5-SR2-Ex1.W KFA5-SR2-Ex1.W.LB KFA5-SR2-Ex2.W KFA5-SR2-Ex2.W.IR KFD2-SH-Ex1.T KFD2-SOT3-Ex2.IO-Y1 KCD2-SON-Ex1.R1  KCD2-SON-Ex1.SP KCD2-SON-Ex2 KCD2-SON-Ex2.R1 KCD2-SON-Ex2.SP KCD2-SOT-Ex1.LB.SP KCD2-ST-Ex1.LB.SP KCD2-ST-Ex2.SP KFA4-SR2-Ex2.W KFA5-DU-Ex1.D KFA4-SR2-Ex1.W KFA4-SR2-Ex1.W.LB KFD2-SOT2-Ex1.LB KFD2-SOT2-Ex1.LB.IO KFD2-SOT2-Ex2 KFD2-SOT2-Ex2.IO KFD2-SOT2-Ex2.IO-Y181008 KFD2-SR2-Ex2.2S KFD2-ST2-Ex1.LB KFD2-ST2-Ex2
	Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	KFD2-STC4-EX1 KFD2-SR2-EX1.W KFD2-SR2-EX2.W KFD2-CD-EX1.32 KFD2-UT2-EX1. KFD2-ST-EX1 KFD2-UFC-EX1.D KFA5-SR2-EX2.W KFA5-SR2-EX1.W KFA6-SR2-EX2.W KFA5-SR2-EX1.W KFD2-ST-EX1 KFD2-SOT2-EX1 KFU8-UFC-EX1.D KFD2-CD-EX1.32 KFU8-FSSP-1.D KFA6-DWB-EX1.D KFD2-DWB-EX1.D KFA5-SR2-EX1,W KFA5-SR2-EX2,W KFD2-VR4-EX1.26 KFD2-STC4-EX1.20 KFD2-SOT2-EX2 KFD2-ST2-EX1.B KFD2-DWB-EX1.D KFD2-UFC-EX1.D KFA6-STR-1.24.500 KFD2-UT2-1 KFD2-UT2-2 KFD2-CD-1.32 KFD2-SOT2-EX1.LB KFA6-SR2-EX1.LB KFA6-SOT2-EX2 KFU8-FSSP-1.D KFU8-UFC-EX1,D KFU8-UFT-EX2.D KFA6-DWB-EX1.D KFD0-SCS-EX1.55 KFD2-STC4-EX2 KFD2-STC4-EX1Y125882 KFD2-UT2-EX2 UPR-03 KFD2-EB2.B4.AB KFD2-CD-EX1.32 KFD2-STC4-EX1 KFD2-UT2-EX1 KFD2-SR2-Ex1.W KFD2-SCD-EX1.LK KFD2-SOT2-EX2 KFD2-STC4-EX2 KFD2-SR2-Ex2.W KFD2-SR2-Ex1.W KFD2-STC4-EX1.2O KFD0-SCS-EX1.55 KFU8-UFC-EX1.D KFD2-SOT2-EX2 KFD2-STC4-EX1 KFD2-UT2-EX2 KFD2-VR4-EX1.26 KFD2-EB2.R4A.B KFD2-BR-1.PA.93 KFU8-DWB-1.D KFU8-DW-1.D KFU8-UFT-EX2.D Z787.H UPR-03
Pepperl+Fuchs KFD0-RO-Ex2 Relay Module KFD0-RO-Ex2 Isolated Barriers Arrived
	We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers,Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
	We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL,Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Moog etc.
	Contact:
	HONGKONG XIEYUAN TECH CO., LIMITED
	Email:becky@hkxytech.com   Web:www.hkxytech.com
	Mobile:+86-15972186287(Whatsapp & Wechat)
	Pepperl+Fuchs KFD0-RSH-1 Relay Module KFD0-RSH-1 Signal Conditioners Arrived
 
			 
		